PIV measurements of the gaseous flow from SpraySyn burner
The dataset was extracted from particle image velocimetry measurements (PIV) of the gaseous flow discharged through the SpraySyn burner at the standard condition SF1 (2ml/min pure ethanol, 10slm dispersion. O2,16slm pilot O2, 2slm pilot CH4, 120slm sheath N2).
Uncertainties within a 95% confidence interval (unc) were computed by the correlation Statistics method.
The underlying methodology is described in the following publication: Martins et al., 2020, Exp. Therm. Fluid Sci. 114, p.110052, DOI:https://doi.org/10.1016/j.expthermflusci.2020.110052. We recommend to cite this paper along with the data DOI when using this material.