Respiration-controlled radiotherapy in lung cancer : Systematic evaluation of the optimal application practice
Background and purpose: Definitive radiochemotherapy(RCT) for non-small cell lung cancer (NSCLC) in UICC/TNM I–IVA (singular, oligometastatic) is one of the treatment methods with a potentially curative concept. However, tumour respiratory motion during RT requires exact pre-planning. There are various techniques of motion management like creating internal target volume (ITV), gating, inspiration breath–hold and tracking. The primary goal is to cover the PTV with the prescribed dose while at the same time maximizing dose reduction of surrounding normal tissues (organs at risk, OAR). In this study, two standardized online breath–controlled application techniques used alternately in our department are compared with respect to lung and heart dose.
Materials and methods:Twenty-four patients who were indicated for thoracic RT received planning CTs in voluntary deep inspiration breath-hold (DIBH) and in free shallow breathing, prospectively gated in expiration (FB-EH). A respiratory gating system by Varian (Real-time Position Management, RPM) was used for monitoring. OAR, GTV, CTV and PTV were contoured on both planning CTs. The PTV margin to the CTV was 5 mm in the axial and 6–8 mm in the cranio-caudal direction. The consistency of the contours was checked by elastic deformation (Varian Eclipse Version 15.5). RT plans were generated and compared in both breathing positions using the same technique,IMRT over fixed irradiation directions or VMAT. The patients were treated in a prospective registry study with the approval of the local ethics committees.
Results:The PTV in expiration (FB-EH) was on average significantly smaller than the PTV in inspiration (DIBH): for tumours in the lower lobe (LL) 431.5 vs. 477.6 ml (Wilcoxon test for connected samples; p = 0.004), in the upper lobe (UL) 659.5 vs. 686.8 ml (p = 0.005). The intra-patient comparison of plans in DIBH and FB-EH showed superiority of DIBH for UL-tumours and equality of DIBH and FB-EH for LL-tumours. The dose for OAR in UL-tumours was lower in DIBH than in FB-EH (mean lung dose p = 0.011; lungV20, p = 0.002; mean heart dose p = 0.016). The plans for LL-tumours in FB-EH showed no difference in OAR compared to DIBH (mean lung dose p = 0.683; V20Gy p = 0.33; mean heart dose p = 0.929). The RT setting was controlled online for each fraction and was robustly reproducible in FB-EH.
Vorschau
Zitieren
Rechte
Nutzung und Vervielfältigung:
Dieses Werk kann unter einerCreative Commons Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 Lizenz (CC BY-NC-ND 4.0)
genutzt werden.